{"created":"2023-06-19T10:37:53.932546+00:00","id":2055,"links":{},"metadata":{"_buckets":{"deposit":"5df09dd1-f9d0-412f-b422-07ebe00135ab"},"_deposit":{"created_by":3,"id":"2055","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"2055"},"status":"published"},"_oai":{"id":"oai:iwate-pu.repo.nii.ac.jp:00002055","sets":[]},"author_link":["4060","4061","4063","4062"],"item_7_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-03-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"25","bibliographicPageStart":"21","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"岩手県立大学盛岡短期大学部研究論集"},{"bibliographic_title":"Bulletin of Morioka Junior College Iwate Prefectural University","bibliographic_titleLang":"en"}]}]},"item_7_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"To examine the distributing warm air to the second floor rooms using under floor heating system, the combined steady state thermal and ventilation network simulation are executed. It is clarified that the heat supply using partition wall cavity (convection walls) is very important to transport warm air to the 2F rooms. The locations of the inlet openings also influence a bit to the formation of homogeneous room temperature in a house. The higher the height of openings on the convection wall is, the smaller the temperature difference among the IF and 2F heating rooms become.","subitem_description_type":"Other"}]},"item_7_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"7","subitem_description_type":"Other"}]},"item_7_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00005384772","subitem_description_type":"Other"}]},"item_7_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"学術論文","subitem_description_type":"Other"}]},"item_7_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"ORIGINAL ARTICLE","subitem_description_type":"Other"}]},"item_7_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA11516689","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13489720","subitem_source_identifier_type":"ISSN"}]},"item_7_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"岩手県立大学盛岡短期大学部生活科学科生活科学専攻"},{"subitem_text_value":"株式会社サンポット研究開発部"}]},"item_7_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"MORIOKA JUNIOR COLLEGE IWATE PREFECTURAL UNIVERSITY"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"本間, 義規"},{"creatorName":"ホンマ, ヨシノリ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"4060","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仁木, 康介"},{"creatorName":"ニキ, コウスケ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"4061","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"HONMA, Yoshinori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"4062","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"NIKI, Kousuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"4063","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-12-27"}],"displaytype":"detail","filename":"KJ00005384772.pdf","filesize":[{"value":"657.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00005384772.pdf","url":"https://iwate-pu.repo.nii.ac.jp/record/2055/files/KJ00005384772.pdf"},"version_id":"fb619af3-12d8-4a10-b3c6-e26850dac435"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"空気循環","subitem_subject_scheme":"Other"},{"subitem_subject":"暖房システム","subitem_subject_scheme":"Other"},{"subitem_subject":"床下空間","subitem_subject_scheme":"Other"},{"subitem_subject":"Air convection","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Heating system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Crawl space","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"床下暖房システムにおける放熱器配置および2階開口位置の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"床下暖房システムにおける放熱器配置および2階開口位置の検討"},{"subitem_title":"Study on the Heater Positioning and the Location of Opening on the Convection Wall for Convective Warm Air Heating System using Crawl Space","subitem_title_language":"en"}]},"item_type_id":"7","owner":"3","path":["288"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-12-27"},"publish_date":"2016-12-27","publish_status":"0","recid":"2055","relation_version_is_last":true,"title":["床下暖房システムにおける放熱器配置および2階開口位置の検討"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-04-22T04:08:27.103849+00:00"}